2023 Ram 1500

Standard Procedure

Corrosion Protection

▸Contents: 31 - Collision Information

Corrosion Protection Restoration

"Corrosion protection" encompasses all the materials and coatings which protect a vehicle from corrosion and include:

  • Coated steels
  • E-coat primer on the complete body
  • Body sealing to eliminate water and air intrusion where panels join
  • Structural adhesives in some joints
  • Chip resistant primer applications on the entire body
  • Paint application
  • Underbody corrosion protection
  • Inner panel corrosion protection added to repair areas
 

Corrosion protection must be restored during a repair anytime it may have been compromised. All areas that have been subjected to structural pulls, clamping, straightening, welding, or any other any other operation that may have imparted damage to the corrosion protection system will need to be addressed.

In the repair process corrosion protection is addressed in three phases: pre-refinish, refinish and post-refinish.


Pre-refinish

In the pre-finish phase, structural adhesives, seam sealers and other applied coatings are installed. Sheet metal seams are sealed to prevent water intrusion into the "dry" areas of the vehicle, such as passenger compartment, and also to prevent intrusions of contaminates, such as water and road salt, into seams causing corrosion. Lap joints, hem flanges, and any panel mating locations need to be addressed during the repair and treated to duplicate the original vehicle build.

All bare metal should be epoxy primed prior to applying seam sealer, following the refinish material provider's instructions for doing so, unless the manufacture of the sealer specifically states otherwise.

When working around pinch weld flanges, seam sealer should be installed to duplicate the original appearance and function. If it is unclear whether the original sealing material between the flanges is strictly a sealer or structural adhesive, always default to a structural adhesive. For additional information related to weld-bonding and welding around adhesives and sealers (Refer to 31 - Collision Information/Standard Procedures/WELDING AND WELD BONDING) .

Roof and closure panels will require the use of anti-flutter foam. Apply where inner panel supports meet external panels..

Any disturbed or removed Noise Vibration Harshness (NVH) foam needs to be replaced.

All hem flanges on closure panels should be sealed whether sealer is apparent or not. This includes those disturbed during the repair, and those on new replacement panels. Either duplicate the existing bead in shape or size, or where one is not obvious, seal the hem flange in a discrete fashion.

Lap joints, such as in floor pans, should be sealed to duplicate the sealer visible, but also addressed on any exterior surface by sealing the lap wether visible or not.



NOTE:

For approved replacement materials including impact resistant grade structural adhesives, sheet metal bonding grade adhesives, anti-flutter adhesives, seam sealers and PUR foams (Refer to 31 - Collision Information/Approved Materials/ADHESIVES SEALERS AND ADDITIONAL MATERIALS) .


NOTE:

FCA US LLC recommends the use of "weld-through" primer during repairs utilizing GMAW (MAG Welding). Weld-bonding with corrosion protecting adhesives or sealers when utilizing Squeeze Type Resistance Spot Welding (STRSW). Following all welding operations the proper method requires a final application of inner panel corrosion protection.


Refinish

All painted surfaces should be coated using a FCA US LLC approved refinish material. The refinish process includes application of undercoats, primers (filler & sealer), basecoats and clearcoat. These approved materials have been tested to the same material standards as the production materials.


Post-refinish

All new panels, and repair areas, must have inner panel corrosion protection applied after the painting operation is complete, but before all the trim is reinstalled. Cavity wax should be applied to all interior cavities, weld flanges, hem flanges as well as any are affected by the repair especially where any type of welding was performed. Inner panel corrosion protection should be applied using "pressure pot" equipment with wands which provide 360-degree material coverage for closed cavities, and directional spray wands for visible coverage. Additionally, the corrosion protecting material must be applied in two coats with a minimum 30-minute flash time between applications.

Wheel wells and underbody panels which have been involved in the repair process should also have a final undercoating applied. Applied with "pressure pot" style application equipment.



NOTE:

For approved cavity wax and undercoating (Refer to 31 - Collision Information/Approved Materials/ADHESIVES SEALERS AND ADDITIONAL MATERIALS) .

Following this arrangement, choice of materials, and proper application, the repaired vehicle should be as well protected against corrosion as it was prior to the repair.